A water bill that jumped 30% with no change in usage. A ceiling stain that keeps reappearing after patches. A soft spot in the flooring with no visible source. These are signs of a hidden leak that's been running long enough to cause structural damage β and every day it runs is money lost and damage accumulating. Masters Plumbing Service uses acoustic ground microphones, thermal imaging cameras, and precision pressure testing in Sunset, LA to locate leaks without speculative demolition.
π Call +1-855-718-1500 β Find Your Leak Today
A pressure test tells us a leak exists and how much water is escaping. Detection equipment tells us precisely where.
Pressurized supply line leaks create a distinctive low-frequency sound as water escapes the pipe and contacts surrounding soil or structure. Our acoustic listening devices amplify this signal, filtered for background noise, so we can walk a grid pattern and triangulate the loudest point β often to within 6β12 inches of the actual break.
Active water leaks β hot or cold β create a temperature differential on the surfaces they contact. An infrared camera shows these differentials as color-coded heat maps, revealing the wet zone inside a wall or under a floor without any cutting. A cold water leak behind drywall appears as a spreading blue-gray cool zone; a hot water leak shows the inverse.
Pressure decay testing is the standard by which we confirm a leak is present before committing detection equipment time. It also tells us approximately how significant the leak is β a rapid pressure drop vs. a slow one indicates the size of the escape point.
Tracer gas detection is the method of last resort for the most challenging cases β it adds cost and setup time. We use it when acoustic and thermal methods haven't produced a definitive location and the evidence clearly supports an active leak.
Our detection service covers the full property, not just the obvious locations.
Confirmed slab leak location is documented with a marked point on the floor and provided to you in the written detection report, with coordinates relative to fixed reference points for the repair crew.
We document the thermal anomaly, mark the approximate pipe location, and recommend a minimal access cut rather than a wide wall opening.
We mark the ground above the detected leak location so the repair crew opens only the section they need to.
Irrigation system leaks in main supply lines and lateral runs are found by isolating zones with the irrigation controller and pressure-testing each zone individually. Zone by zone testing narrows the failure to the smallest possible section.
Multi-story buildings, commercial kitchens, retail spaces, and industrial properties have complex pipe networks where a supply or drain leak can go undetected through multiple floors before surfacing. We approach commercial detection systematically β zone by zone pressure isolation, thermal scan of suspect surfaces, and acoustic confirmation.
Insurance claims for water damage from hidden leaks typically require documentation that the leak was not visible or detectable without specialized equipment. Our detection report includes: pressure test results confirming active water loss, detection method used, thermal imagery or acoustic mapping showing leak location, and technician certification information.
Here's exactly how a Masters Plumbing Service leak detection call plays out.
This step confirms we're looking for a real leak rather than meter error or a normal appliance cycling.
Zone isolation is the step that turns "there's a leak somewhere in the house" into "the leak is on the hot side supply, between the water heater and the master bath."
We document findings with thermal images and note detection readings at multiple grid points to triangulate the strongest signal.
Insurance claims: the report is formatted to support a claim for water damage from a concealed leak. We can provide supplemental documentation on request.

High-efficiency home with a leak that defied normal detection. Water loss was slow β about 1.5 gallons per hour. The tech used tracer gas after pressure testing confirmed the loss but acoustic detection couldn't localize it clearly. Gas detection found the escape at a micro-fitting under the slab in the utility corridor. Impressive work.
Ceiling stain in the living room kept coming back despite two drywall patches. Masters Plumbing Service ran the thermal camera and found the wet zone was traveling from a supply line joint 9 feet away and flowing down a horizontal framing member β explaining why the patch kept failing. They marked the actual pipe location, we opened 8 inches of wall there, and the repair held. No more stain.
Commercial building where water costs were running 40% above baseline for six months. Masters Plumbing Service ran a systematic zone-by-zone pressure isolation across four floors, narrowed the loss to the third-floor kitchen supply branch, and located the failure with thermal imaging at a concealed valve body in the ceiling. No damage to the finished ceiling.

Our detection technicians are equipped with acoustic, thermal, and tracer gas tools for the full range of leak scenarios found in Sunset, LA homes and commercial properties.

Call now to schedule β most detection appointments available within 24β48 hours.